These are automatic self-service vending machines that dispense gaming metal token against receipt of bank notes. Advanced technology is widely utilized by our professionals in developing these machines. We offer these machines to the customers at industry leading prices.
Type - Wall Mountable
Purpose - Burn used Sanitary Napkins to sterile ash and stop automatically
Color - Pink
Operation Mode - Electronically operated, fully Automatic
Loading Type - Front loading
Stand provided - No
Number of chambers - Two
Trap Door available - Yes
All MS parts Powder coated - Yes
Spare parts should be available for Minimum 5 years from date of supply - Yes
All electrical parts are ISI Marked - Yes
Thickness of thermal Insulation material (mm) - 40 millimeter
Thickness of MS/SS sheet of housing cabinet (external) (mm) - 1.2 millimeter
Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) - 3 millimeter
Machine Width(mm) - 200-300
Machine Depth (mm) - 201-300
Machine Hight(mm) 200-500
Machine Weight(kg) 16-30
Door width(mm) 101-150
Door height(mm) 151-200
Thickness of door including insulation (mm) - 40 millimeter
Internal/burning chamber shape - Vertical cylindrical
Flexible emission Outlet pipe dia (mm) - 50 millimeter
Detachable ash tray length (mm) - 151-200
Detachable ash tray width (mm) - 151-200
Detachable ash tray height (mm) - 16-30
Stand Height (mm) - 600 millimeter
Stand Width (mm) - 401-800
Stand Depth (mm) - 201-300
Material of Housing cabinet (External) - Mild Steel(CRCA) sheet
Material of Burning chamber (Internal) - Mild Steel(CRCA) sheet
Finish of MS parts of cabinet - Epoxy anti rust proof painting for superior finish
Material of Thermal Insulation - High Density Ceramic Board
Thermal insulation of burning chamber housed in outer chamber - Yes
Burning Chamber tray provided - Yes
Emission Outlet pipe location - Top of machine
Means of connecting the unit outlet with flue gas emission pipe - Clamped
Type of door lock provided - Magnetic lock
Temperature indicator provided - Yes
Timer provided - Yes
Auto cut-off temperature display - Yes
Digital display to see actual and set temperature - Yes
Minimum Burning temperature (degree C) - 800
Burning Capacity per day (Number of Napkins) - 51-100
Burning Capacity at a time (Number of Napkins) - 1-15
Residue Ash per Napkin (gms) - 1.25 gram
Burning time of full capacity Napkins/pads (minutes) (Max) - 5 minute
Skin temperature of the unit under operation (deg C) - 0-15
Installation, training, demonstration and plumbing included - Yes
Automatic digital controller for time - Yes
Automatic digital controller for temperature - Yes
Equipment ON/OFF indicator provided - Yes
Power supply - 230v +/-10%, 50Hz, Single phase, AC supply
Electrical Power Consumption(Watt) - 1001-1500
Minimum length of power chord to be supplied along with machine (mtr) - 2 meter
Type of Heater - Ceramic heater containing coil
Power saver (auto power cut-off) - Yes
Safety MCB provided (16A to 30A) Yes
Protection against electric shock when checked as per IS:302-1/2008 - Yes
Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) - 2
Maximum Electrical Insulation and Leakage current as per IS:302-1/2008, (mA) - 0.21
Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) - 0.1
HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 - No breakdown shall occur during the test.
Type of SCU (Smoke Control Unit) - Top mounted
Material of housing of Smoke Control Unit (SCU) - Mild Steel(CRCA) cabinet
Finish of MS parts of SCU cabinet - Epoxy anti rust proof painting for superior finish
Overall height of SCU (mm) - 300
Overall width of SCU (mm) - 301-500
Overall depth of SCU (mm) - 301-500
Number of chambers for filteration of smoke emission- Two
Both carbon Control and Foul odour Control Chambers for filteration of smoke emission - Yes
Number of filters in Carbon control chamber - Two
Type of filters in Carbon control chamber - Activated Carbon filter
Number of filters in Odour control chamber - Two
Type of filters in Odour control chamber - Activated Carbon filter
Blower type "Centrifugal, direct driven"
Blower RPM 1800
Power supply of SCU - 230v +/-10%, 50Hz, Single phase, AC supply
Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) - 3
Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user - Yes
Conformity to CPCB, Min of Environment & Forests standard, Solid Waste Management Rules (SWM), 2016 - Yes
Particulates (Half hourly average) (mg/Nm3) (Max) - 50
HCl (Half hourly average) (mg/Nm3) (Max) - 50
SO2 (Half hourly average) (mg/Nm3) (max) - 200
CO (Half hourly average) (mg/Nm3) (Max) - 100
CO (Daily average) (mg/Nm3) (Max) - 50
Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) - 20
HF (Half hourly average) (mg/Nm3) (Max) - 4
"Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" - 400
Total dioxins and furans ( 6 to 8 hours sampling basis, Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) - 0.1
Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) - 0.5
Loss on ignition (max) (% dry weight of the material) - 5
Packing - Carton Box
The appliance is marked as per IS:302-1/2008 - Yes
Submission of Test Report from Central Govt/CSIR Lab/NABL/ILAC accredited Lab specifically containing Electrical & Electronic parameters,Thermal insulation material of burning chamber in addition to declared specification parameter at time of supply - Yes
Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollution Control Board (CPCB) norms from NABL accredited lab/CSIR Lab at the time of supply - Yes
Certification Available - EU-CE,BIS,US-FDA,Other,CSIR-NEERI
Certificate for Manufacturing premises available - ISO
Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier - Yes
Submission of all the certifications to the buyer along with supplies - Yes
Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) - 2