GENERAL

Type - Wall Mountable

Purpose - Burn used Sanitary Napkins to sterile ash and stop automatically

Color - Pink

Operation Mode - Electronically operated, fully Automatic

Loading Type - Front loading

Stand provided - No

Number of chambers - Two

Trap Door available - Yes

All MS parts Powder coated - Yes

Spare parts should be available for Minimum 5 years from date of supply - Yes

All electrical parts are ISI Marked - Yes

DIMENSIONS OF MAIN UNIT

Thickness of thermal Insulation material (mm) - 40 millimeter

Thickness of MS/SS sheet of housing cabinet (external) (mm) - 1.2 millimeter

Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) - 3 millimeter

Machine Width(mm) - 200-300

Machine Depth (mm) - 201-300

Machine Hight(mm) 200-500

Machine Weight(kg) 16-30

Door width(mm) 101-150

Door height(mm) 151-200

Thickness of door including insulation (mm) - 40 millimeter

Internal/burning chamber shape - Vertical cylindrical

Flexible emission Outlet pipe dia (mm) - 50 millimeter

Detachable ash tray length (mm) - 151-200

Detachable ash tray width (mm) - 151-200

Detachable ash tray height (mm) - 16-30

Stand Height (mm) - 600 millimeter

Stand Width (mm) - 401-800

Stand Depth (mm) - 201-300

MATERIAL OF MACHINE UNIT

Material of Housing cabinet (External) - Mild Steel(CRCA) sheet

Material of Burning chamber (Internal) - Mild Steel(CRCA) sheet

Finish of MS parts of cabinet - Epoxy anti rust proof painting for superior finish

Material of Thermal Insulation - High Density Ceramic Board

CONSTRUCTIONAL FEATURES

Thermal insulation of burning chamber housed in outer chamber - Yes

Burning Chamber tray provided - Yes

Emission Outlet pipe location - Top of machine

Means of connecting the unit outlet with flue gas emission pipe - Clamped

Type of door lock provided - Magnetic lock

CONTROL & FUNCTIONAL FEATURES

Temperature indicator provided - Yes

Timer provided - Yes

Auto cut-off temperature display - Yes

Digital display to see actual and set temperature - Yes

Minimum Burning temperature (degree C) - 800

Burning Capacity per day (Number of Napkins) - 51-100

Burning Capacity at a time (Number of Napkins) - 1-15

Residue Ash per Napkin (gms) - 1.25 gram

Burning time of full capacity Napkins/pads (minutes) (Max) - 5 minute

Skin temperature of the unit under operation (deg C) - 0-15

Installation, training, demonstration and plumbing included - Yes

ELECTRICAL AND SAFETY FEATURES

Automatic digital controller for time - Yes

Automatic digital controller for temperature - Yes

Equipment ON/OFF indicator provided - Yes

Power supply - 230v +/-10%, 50Hz, Single phase, AC supply

Electrical Power Consumption(Watt) - 1001-1500

Minimum length of power chord to be supplied along with machine (mtr) - 2 meter

Type of Heater - Ceramic heater containing coil

Power saver (auto power cut-off) - Yes

Safety MCB provided (16A to 30A) Yes

Protection against electric shock when checked as per IS:302-1/2008 - Yes

Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) - 2

Maximum Electrical Insulation and Leakage current as per IS:302-1/2008, (mA) - 0.21

Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) - 0.1

HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 - No breakdown shall occur during the test.

SMOKE CONTROL UNIT (SCU)

Type of SCU (Smoke Control Unit) - Top mounted

Material of housing of Smoke Control Unit (SCU) - Mild Steel(CRCA) cabinet

Finish of MS parts of SCU cabinet - Epoxy anti rust proof painting for superior finish

Overall height of SCU (mm) - 300

Overall width of SCU (mm) - 301-500

Overall depth of SCU (mm) - 301-500

Number of chambers for filteration of smoke emission- Two

Both carbon Control and Foul odour Control Chambers for filteration of smoke emission - Yes

Number of filters in Carbon control chamber - Two

Type of filters in Carbon control chamber - Activated Carbon filter

Number of filters in Odour control chamber - Two

Type of filters in Odour control chamber - Activated Carbon filter

Blower type "Centrifugal, direct driven"

Blower RPM 1800

Power supply of SCU - 230v +/-10%, 50Hz, Single phase, AC supply

Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) - 3

Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user - Yes

EMISSION STANDARD FOR SMOKE

Conformity to CPCB, Min of Environment & Forests standard, Solid Waste Management Rules (SWM), 2016 - Yes

Particulates (Half hourly average) (mg/Nm3) (Max) - 50

HCl (Half hourly average) (mg/Nm3) (Max) - 50

SO2 (Half hourly average) (mg/Nm3) (max) - 200

CO (Half hourly average) (mg/Nm3) (Max) - 100

CO (Daily average) (mg/Nm3) (Max) - 50

Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) - 20

HF (Half hourly average) (mg/Nm3) (Max) - 4

"Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" - 400

Total dioxins and furans ( 6 to 8 hours sampling basis, Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) - 0.1

Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) - 0.5

Loss on ignition (max) (% dry weight of the material) - 5

PACKING

Packing - Carton Box

MARKING AND INSTRUCTIONS

The appliance is marked as per IS:302-1/2008 - Yes

CERTIFICATION

Submission of Test Report from Central Govt/CSIR Lab/NABL/ILAC accredited Lab specifically containing Electrical & Electronic parameters,Thermal insulation material of burning chamber in addition to declared specification parameter at time of supply - Yes

Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollution Control Board (CPCB) norms from NABL accredited lab/CSIR Lab at the time of supply - Yes

Certification Available - EU-CE,BIS,US-FDA,Other,CSIR-NEERI

Certificate for Manufacturing premises available - ISO

Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier - Yes

Submission of all the certifications to the buyer along with supplies - Yes

PERFORMANCE REQUIREMENTS

Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) - 2